2019年11月1日星期五

How to connect water inlet and outlet between chiller and laser

Now,I will show you How to connect the water inlet and outlet

This is water inlet of S&A chiller
"inlet"marked on the sheet metal of chiller
This is water outlet of S&A chiller
"outlet"marked
You will also find the same label on the laser machine
Pls connect the outlet of chiller to the inlet of laser
Connect the intlet of chiller to the outlet of laser
Caution:Incorrect operation will damage the laser
Besides, there is no tag of inlet & outlet on laser machine
Please contact the laser equipment factory
Thanks for using S&A chiller!

CONTACT S&A

TE:+86-20-89301885

FAX:+86-20-84309967

SKYPE: teyuchiller

Email:

Website: http://

The 3S127 series plunger pump is also developed for the high pressure process requirements of the oil field. The service life of all kinds of vulnerable parts is also greatly improved. The hydraulic end of the pump uses high pressure water injection multi cavity reciprocating combination pump head structure, which has the characteristics of simple structure, convenient operation and maintenance and high pump efficiency.