2019年11月3日星期日

Centrifugal pump three maintenance methods

[Asia pump network] Xiaobian today and we introduce the next three centrifugal pump maintenance methods. We pay attention to the maintenance process, you can extend the life of centrifugal pumps. Centrifugal pump three maintenance methods Centrifugal pump first-class maintenance Centrifugal pump cumulative operation (1000 ± 24) h, the duty by a maintenance personnel, the main contents, 1, check the coupling (back wheel, the wheel) In good condition, tighten the bolt, improve health work. 2, replace or fill with sealing packing, so gland parallel press-in, gland packing box from the end face distance of not more than 5mm, no more than 30 drops per minute leakage. 3, check and clean the bearings, add or replace the lubricating oil. 4, check and clean the import filter, proofreading import and export pressure gauge. 5, check the motor bearings and raise the oil. 6, check and tighten the bolts of the various parts of the unit to deal with the leakage of the various sections of the pipeline. Centrifugal pump secondary maintenance Centrifugal pump cumulative operation (3000 ± 24) h, the maintenance of large classes or mechanics mainly by the duty staff with secondary maintenance operations. 1, will be a maintenance job completed all over again. 2, measuring and checking the bearing clearance, if necessary, to adjust and replace, to ensure that the gap in line with the provisions. 3, check the work of the pump string (balancing disk gap). 4, check the coupling of concentricity. Centrifugal pump three maintenance Centrifugal pump cumulative operation (10000 ± 72) h, by the pump repair professionals at the scene for three maintenance operations. 1, remove and connect all the pipe and pump outlet flange, and inspection and cleaning, to be unimpeded, no damage. 2, remove the pump: After loosening the tile cover bolts, remove the tile and the tile, remove the tile frame and the tail cover. (Editor: Xiaoxia QQ:) Recommended reading: 2017 exhibition information

Serrated Steel Grating Specifications (mm):
Steel Grating Size: 1m*6m standard type (special size and American standard size are also customizable)
Material: Low carbon steel (Q235)
Surface Treatment: Hot dip galvanizing, paint or no coating
Surface Shape: Planform, tooth shape and I shape

Serrated Steel Grating

Quality Standard:
Steel Grating Standard: China YB/T4001-1998
America ANSI/NAAMM (MBG531-88)
Britain BS4592-1987
Australia AS1657-1992
Steel Standard: China GB700-88 / ASTM (A36) / BS4306 (43A)
Hot Dip Galvanizing Standard: China GB/T13912-92 / ASTM (A123) / BS729


Serrated Steel GratingSerrated Steel Grating


Serrated Steel Grating Surface Treatment:

  • Untreated
  • Painting
  • Hot Dip Galvanizing

Serrated Steel Grating Application:
Widely used in power plants, refineries, sewage treatment plants, silos, chemical plants, highways, airports and docks and other platforms, walkways and gutter covers, stair step. Tooth steel grating which can be used for wet, slippery places, especially for offshore oil platforms.

Serrated Steel GratingSerrated Steel Grating


Serrated Steel Grating

Serrated Steel Grating,Serrated Galvanized Steel Grating,Galvanized Serrated Steel Grating,Catwalk Serrated Steel Grating

Hebei Zhenxing Jinyuan Wire Mesh Group Co.,Ltd , https://www.zxsteelgrating.com

没有评论:

发表评论