Centrifugal pump in the installation process needs to take into account the height, because this factor will be determined by the centrifugal pump suction, but what is the relationship between the two? In fact, even if we can know that a certain suction centrifugal pump should be installed at how much height. Centrifugal pump installation height and the suction stroke of the selection of a key centrifugal pump installation technology Centrifugal pump installation technology is the key to determine the installation of the pump height (suction). This height refers to the vertical distance from the water surface of the water source to the center line of the pump impeller. It can not be confused with the allowable vacuum height. The allowable vacuum height indicated on the pump manual or nameplate means the vacuum value on the water inlet section of the water pump, Is measured at 1 standard atmospheric pressure, the water temperature of 20 degrees Celsius, the test. It does not consider the condition of the water flow after the water supply pipe is matched. The pump installation height should be allowed to suck vacuum height deducted after the loss of suction pipe head, the remaining part of the value, it is necessary to overcome the actual terrain water absorption height. Pump installation height can not exceed the calculated value, otherwise, the pump will not pump water. In addition, the impact of the calculated value is the size of the suction pipe lift loss lift, it is appropriate to use the shortest pipe layout, and try to install less elbow and other accessories, but also consider the appropriate with some larger diameter pipes to reduce the flow rate within the pipe. It should be noted that the pipelines centrifugal pump installation site elevations and water temperature is different from the test conditions, such as the local elevation of 300 meters above or pumping water temperature exceeds 20 degrees Celsius, the calculated value to be amended. Ie atmospheric pressure at different elevations and saturated vapor pressure above 20 degrees Celsius. However, when the water temperature is below 20 degrees Celsius, the saturated steam pressure is negligible. From the pipe installation technology, the suction pipe requires strict sealing, can not leak, leakage, otherwise it will undermine the pump inlet of the vacuum, so that the water pump to reduce the amount of water is not even pumping in serious cases. Therefore, we should conscientiously do the work of the interface of the pipeline to ensure the construction quality of pipeline connection. Second, the installation of centrifugal pump height Hg Allowable vacuum suction height Hs refers to the pressure at the pump entrance p1 allows the maximum degree of vacuum. The actual allowable suction height, Hs, is not a value calculated according to the equation, but a value determined experimentally by the pump manufacturer, which is attached to the pump sample for user investigation. It should be noted that the value of Hs given in the pump sample is the value of water used as working medium, operating conditions of 20 ℃ and pressure of 1.013 × 105Pa, when the operating conditions and working medium are different, need to be converted. (1) Conveying clear water, but the operating conditions and experimental conditions are different and can be converted into Hs1 = Hs + (Ha-10.33) - (Hυ-0.24) according to the following formula. The conditions are different, the need for two-step conversion: The first step according to the formula will be detected by the pump sample Hs1; The second step according to the following formula Hs1 H? S2 NPSH Δh For the pump, calculate the installation height Calculate the amount of cavitation allowance Δh, that is, the degree of vacuum that the pump allows to draw liquid, that is, the allowable installation height of the pump, in meters. Naphthenic residual amount Δh by the pump in the sample, its value is also measured with 20 ℃ water. If you transfer other liquids, also need to be corrected, detailed investigation of the books. Stroke = standard atmospheric pressure (10.33 meters) - NPSH - safe amount (0.5 meters) Standard atmospheric pressure can depress the pipeline vacuum height of 10.33 meters. For example: a pump required NPSH of 4.0 meters, seeking suction Δh solution: Δh = 10.33-4.0-0.5 = 5.83 meters From a safety point of view, the actual installation of the pump height value should be less than the calculated value. When the calculated value of Hg is negative, it indicates that the suction port of the pump should be below the level of the tank. Example 2-3 A centrifugal pump from the sample was allowed to suction on the vacuum height Hs = 5.7m. It is known that the total resistance of the suction line is 1.5 mH2O and the local atmospheric pressure is 9.81 × 10 4 Pa. The dynamic head of liquid in the suction line is negligible. Try to calculate: (1) pump installation 20% water delivery; (2) to the delivery of 80 ℃ water pump installation height. Solution: (1) The installation height of the pump when delivering 20 ℃ fresh water is known: Hs = 5.7m Hf0-1 = 1.5mu12 / 2g≈0 The local atmospheric pressure is 9.81 × 104Pa, which basically agrees with the experimental conditions of the pump factory Pump installation height Hg = 5.7-0-1.5 = 4.2m. (2) Installation height of pump when conveying water at 80 ℃ When installing water at 80 ℃, the installation height can not be directly calculated by using the Hs value in the pump sample. Hs1 = Hs + (Ha-10.33) - (Hυ-0.24) Known Ha = 9.81 × 104Pa≈10mH2O, from the appendix to find the saturated vapor pressure of water at 80 ℃ 47.4kPa. Hv = 47.4x103Pa = 4.83mH2O Hs1 = 5.7 + 10-10.33-4.83 + 0.24 = 0.78m The Hs1 value is substituted into the equation to find the installation height Hg = Hs1-Hf0-1 = 0.78-1.5 = -0.72m Hg is negative Value, indicating that the pump should be installed below the tank level, at least 0.72 m below the liquid level. (Editor: Yunhai QQ:) Recommended reading: 2017 exhibition information
Table-Top Autoclave, also known as the desktop fast sterilizer, has a 4-6 minute quick sterilization function. Producing saturated pressure through steam and achieving the goal of rapid sterilization.
The Steam Sterilizer applies to the Department of stomatology for all kinds of metal equipment and basic equipment sterilization.
Desktop rapid sterilizer function:
1. quick sterilization for 4-6 minutes
2. microcomputers display working state, touch keys
3. there are three fixed sterilization procedures and user adjustable procedures.
4. automatic control in the whole process of adding water, heating, sterilization, exhaust and drying.
5. the internal circulation system of steam water does not exhaust steam, and the environment is clean and dry.
6. automatic emission of cold air
7. water break protection control
8. door safety interlocking device
9. with four layers of stainless steel disinfectant plate
10. the sterilization room is made of high quality stainless steel.
11. the end of the sterilization cycle reminding the automatic stop
Capacity: 20L, 24L, 35L, 50L.
For more models and more product information, please contact our salesperson.
Table-top Autoclave
Table-Top Autoclave,Table-Top Class N Autoclave Sterilizer,Table-Top Table Steam Autoclave,Table-Top Steam Dental Autoclave,Table-top Steam Sterilizer,Table-top Autoclave Sterilizer
Zhengzhou mingyi instrument equipment co.,ltd , https://www.mingyint.com
Wow, you know a lot about centrifugal pump. thanks for sharing. I'm appreciated!
回复删除