2019年10月31日星期四

Magnetic pump should pay attention to what maintenance and maintenance work?

Magnetic Pump (Magnetic Pump) Magnetic pump is a new product that applies the working principle of permanent magnet coupling to centrifugal pump. It has reasonable design, advanced technology, full sealed, no leakage and corrosion resistance. Magnetic pump should pay attention to what the maintenance and repair work Magnet pump in the daily use process Bennett valve recommended that the majority of users should do the following maintenance work: (1) check the magnetic pump lines and joints with loose phenomenon. Rotate the magnetic pump by hand to see if the magnetic pump is spirited. (2) If there is abnormal sound of magnetic pump should stop immediately check the reasons. (3) Unscrew the diversion screw plug of the magnetic pump body, and pour water (or slurry). (4) close the outlet valve and outlet pressure gauges and import vacuum gauge. (5) Move the motor to see if the motor is steered correctly. (6) magnetic pump in operation, the bearing temperature can not exceed the ambient temperature 35C, the maximum temperature shall not exceed 80C. (7) try to control the flow and head of the magnetic pump in the range indicated on the plate to ensure that the maximum efficiency of the magnetic pump operation, in order to get the maximum energy-saving effect. (8) start the motor, when the normal operation of the magnetic pump, open the outlet pressure gauge and inlet vacuum pump as it shows the appropriate pressure, and gradually open the valve, while checking the motor load conditions. (9) Add bearing lubricating oil to the bearing body, observe the oil level should be at the center line of the oil standard, lubricating oil should be replaced or replenished promptly. (10) to stop using the magnetic pump, first close the gate valve, pressure gauge, and then stop the motor. (11) magnetic pump in the first month of work, after 100 hours to replace the oil, after every 500 hours, oil change time. (12) Often adjust the packing gland to ensure normal drip leakage in the packing room. (13) Regular inspection of the sleeve wear, wear and tear should be promptly replaced. (14) When the magnetic pump is used in the winter season, after stopping the pump, unscrew the drain plug at the lower part of the pump to release the medium. Prevent cracking. (15) long-term deactivation of the magnetic pump, pump all the necessary open, dry the water, the rotating parts and joints coated with grease installed. (Editor: LLX QQ:) Recommended reading: 2017 Exhibition Information 2016 Yiwu Fair

FRP Grating

FRP Grating,Frp Panels ,Fiberglass Reinforced Panels ,Fiber Reinforced Plastic Sheet

FRP/GRP Co., Ltd. , http://www.nbfrpproduct.com

没有评论:

发表评论